The medium / high pressure test plug is intended to check the pressure test at the end of the pipeline from 0 to 100 bar for ship, compressed air, building, industrial construction etc. There is no problem in repeated use and reduce costs and improve operational efficiencies is to the user in maintaining the pressure in the pipe.

LOW PRESSURE TEST PLUG (5-10Kg/㎠)

Purpose of Using the High Pressure Test Plug
The low pressure test plug is intended to check the pressure test at the end of the pipeline from 0 to 5 bar. There is no problem in repeated use and reduce costs and improve operational efficienciesis to the user in maintaining the pressure in the pipe.

HYDRO Test Plugs Reports for Steel Pipes
SIZE Schedule High Pressure Test Plugs
Torque
(N.m)
Working Pressure
(kgf/㎠)
Bursting Pressure
(Kgf/㎠)
25A #40
#80
30
20
17.5
25.0
70
100
32A #40
#80
80
60
25.0
25.0
100
100
40A #40
#80
100
70
22.5
25.0
90
100
50A #40
#80
140
80
12.5
22.5
50
90
65A #40
#80
140
80
12.5
25.0
50
100
80A #40
#80
200
160
10.0
20.0
40
80
100A #40
#80
240
240
11.3
13.8
45
55
125A #40
#80
260
240
7.5
22.5
30
90
150A #40
#80
280
240
5.0
20.0
20
80
SIZE Schedule Low Pressure Test Plugs
Torque
(N.m)
Working Pressure
(kgf/㎠)
Bursting Pressure
(Kgf/㎠)
25A #40
#80
30
25
2.0
2.0
6.0
6.0
32A #40
#80
40
35
2.7
3.0
8.0
9.0
40A #40
#80
50
45
2.0
2.3
6.0
7.0
50A #40
#80
80
60
3.0
3.0
9.0
9.0
65A #40
#80
140
120
2.0
2.0
6.0
6.0
80A #40
#80
200
180
2.0
2.3
6.0
7.0
100A #40
#80
240
220
1.5
1.5
4.5
4.5
125A #40
#80
260
240
1.3
1.5
4.0
4.5
150A #40
#80
280
280
1.2
1.2
3.5
3.5
HYDRO Test plugs Reports for CPVC
SIZE Schedule High Pressure Test Plugs
Torque
(N.m)
Working Pressure
(kgf/㎠)
Bursting Pressure
(Kgf/㎠)
32A #80 50 17.5 70
40A 60 17.5 70
50A 60 10.0 40
65A 70 7.5 30
80A 120 7.5 30
100A 150 7.5 30
SIZE Schedule High Pressure Test Plugs
Torque
(N.m)
Working Pressure
(kgf/㎠)
Bursting Pressure
(Kgf/㎠)
32A #80 50 2.7 8.0
40A 60 2.7 8.0
50A 60 2.7 8.0
65A 80 2.5 7.5
80A 100 2.5 7.5